ZP Series

     ZP Series

Model

of Genset

kVa kW

Fuel

Consumption

(L/hr)

Model of Engine

Discharge

(L)

Model of Alternator

Size

(mm)

Weight

(kg)

Prime

Power

Standby

Power

Prime

Power

Standby

Power

ZP11E 10 11 8 8.8 2.8 Perkins 403D-11G

1.13

LSA4.2VS0

1320x552x1179

307

ZP14E

12.5

14

10

11.2

4.0

Perkins 403D-15G

1.5

LSA42.2SVS1

1320x552x1179

393

ZP22E

20

22

16

17.6

5.9

Perkins 404D-22G

2.2

LSA42.2S5

1320x552x1179

460

ZP33E

30

33

24

26.4

7.6

Perkins 1103A-3G

3.3

LSA42.2L9

1770x714x1368

810

ZP50E

45

50

36

40

11.9

Perkins 1103A-33TG1

3.3

LSA43.2S25

2150x752x1366

884

ZP66E

60

66

48

53

15.4

Perkins 1103A-33TG2

3.3

LSA43.2M45

2150x752x1366

874

ZP88E

80

88

64

70

25.1

Perkins 1104A-44TG2

4.0

LSA43.2L8

2149x752x1366

990

ZP110E

100

110

80

88

24.1

Perkins 1104C-44TAG2

4.41

LSA44.2VS45

2370x735x1381

1167

ZP110E

100

110

80

88

26.1

Perkins 1006TG2A

5.99

LSA44.2VS45

2515x735x1545

1191

ZP150E

135

150

108

120

34.4

Perkins 1006TAG

6.0

LSA44.2M95

2675x900x1460

1480

ZP165E

150

165

120

132

33.5

Perkins 1006TAG2

5.99

LSA44.2M95

2675x900x1564

1515

ZP200E

180

200

144

160

44.0

Perkins 1106C-E66TAG4

8.7

LSA46.2M3

2953x1003x1717

1990

ZP220E

200

220

160

176

49.1

Perkins 1306C-E87TAG3

8.7

LSA46.2M5

2953x1003x1717

2009

ZP250E

230

250

184

200

61.2

Perkins 1306C-E87TAG4

8.7

LSA46.2L6

2960x1003x1718

2100

ZP275E

250

275

200

220

63.3

Perkins 1306C-E87TAG6

8.7

LSA46.2L6

2960x1003x1718

2215

ZP385E

350

385

280

308

76.1

Perkins 2206C-E13TAG2

12.5

LSA47.2VS1

3500x1100x2158

2670

ZP440E

400

440

320

352

88

Perkins 2206C-E13TAG3

12.5

LSA47.2S4

3500x1100x2158

2814

ZP500E

450

500

360

400

98.6

Perkins 2506C-E15TAG1

15.5

LSA47.2S5

3700x1100x2143

3793

ZP550E

500

550

400

440

106.8

Perkins 2506C-E15TAG2

15.2

LSA47.2M7

3700x1100x2143

3920

ZP660E

600

660

480

528

131.1

Perkins 2806A-E18TAG1A

18.1

LSA47.2L9

4111x1536x2248

4717

ZP688E

625

688

500

550

137.6

Perkins 2806A-E18TAG2

18.1

LSA49.1S4A

4111x1536x2246

4800

ZP6800E

730

800

584

640

184

Perkins 4006-23TAG3A

22.9

LSA49.1M6

4283x1912x2286

62259

ZP900E

800

900

640

720

184

Perkins 4006-23TAG3A

22.9

LSA49.1M75

4283x1912x2286

6259

ZP1000E

910

1000

728

800

242

Perkins 4008TAG2A

30.6

LSA49.1L10

4790x2036x2235

7334

ZP1100E

1000

1100

800

880

242

Perkins 4008TAG2A

30.6

LSA50.2S4

4790x2036x2235

7334

ZP1375E

1250

1375

1000

1100

283.8

Perkins 4012-46TWG2A

45.8

LSA50.2M6

4887x1895x2380

9059

ZP1650E

1500

1650

1200

1320

329.0

Perkins 1012-46TAG2A

45.8

LSA50.2L8

5095x1900x2435

9720

ZP2000E

1825

2000

1460

1600

400.4

Perkins 4016TAG

61.1

LSA51.2S55

5927x2300x3010

15430

ZP2200E

2000

2200

1600

1760

474

Perkins 4016TAG2A

6.1

LSA51.2M60

5927x2300x3020

15500

ZP2500E

2250

2500

1800

2000

474

Perkins 4016-61TRG3A

61.1

LSA51.2VL85

59525x2300x3020

15500

  1. Output voltage 230V / 400V.
  2. Frequency 50Hz, 60Hz products can refer to the technological specification manual.
  3. The prime power: based on ISO8528-3 standards, it has no time limitation on supply under the variable load. And based on ISO3046-1, it permits less than 10% over load operation within one hour in every 12 hours.
  4. Based on ISO8528-3 standards, the standby power is already adjusted to the highest supplying power, therefore, overload operation is prohibited.
  5. The size and weight are applied to the non-box type of genset of non-optional parts.
  6. Net weight: without fuel.